俄罗斯XXXXXBBBBB


    EN

    產品中心

    大鼠白介素12(IL12)酶聯免疫吸附檢測試劑盒
    ELK9251
    規格: 價格:
    48 T ¥1680.00
    96 T ¥2400.00

    Overview

    Product name: Rat IL12(Interleukin 12) ELISA Kit
    Reactivity: Rat
    Alternative Names: IL-12;Interleukin 12; IL12/P70; Interleukin-12/P70
    Assay Type: Sandwich
    Sensitivity: 1.31 pg/mL
    Standard: 200 pg/mL
    Range: 3.13-200 pg/mL
    Sample type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
    Assay length: 3.5h
    Research Area: Cytokine;Infection immunity;
    Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Interleukin 12(IL12). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Interleukin 12(IL12). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Interleukin 12(IL12), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Interleukin 12(IL12) in the samples is then determined by comparing the OD of the samples to the standard curve.

    標準曲線

    Concentration (pg/mL) OD Corrected OD
    200.00 2.179 2.086
    100.00 1.612 1.519
    50.00 1.128 1.035
    25.00 0.813 0.720
    12.50 0.577 0.484
    6.25 0.336 0.243
    3.13 0.226 0.133
    0.00 0.093 0.000

    精密度

    Intra-assay Precision (Precision within an assay):CV%<8%

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

    Inter-assay Precision (Precision between assays):CV%<10%

    Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

    回收率

    Matrices listed below were spiked with certain level of recombinant IL12 and the recovery rates were calculated by comparing the measured value to the expected amount of IL12 in samples.
    Matrix Recovery range Average
    serum(n=5) 96-107% 102%
    EDTA plasma(n=5) 86-99% 92%
    Heparin plasma(n=5) 82-94% 88%

    線性

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL12 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
    Matrix 1:2 1:4 1:8 1:16
    serum(n=5) 82-96% 88-101% 90-99% 87-98%
    EDTA plasma(n=5) 95-102% 86-97% 88-95% 87-98%
    Heparin plasma(n=5) 86-97% 90-101% 93-101% 93-102%