俄罗斯XXXXXBBBBB


    EN

    產品中心

    哺乳動物雷帕霉素靶蛋白(mTOR)酶聯免疫吸附檢測試劑盒
    ELK9237
    規格: 價格:
    48 T ¥1960.00
    96 T ¥2800.00

    Overview

    Product name: Human MTOR(Serine/threonine-protein kinase mTOR) ELISA Kit
    Reactivity: Human
    Alternative Names: FRAP; FRAP1; FRAP2; MTOR; RAFT1; RAPT1; FK506 Binding Protein 12 Rapamycin Associated Protein; Mammalian Target Of Rapamycin; FKBP12-Rapamycin Complex-Associated Protein 1; Rapamycin and FKBP12 target
    Assay Type: Sandwich
    Sensitivity: 0.125 ng/mL
    Standard: 20 ng/mL
    Range: 0.32-20 ng/mL
    Sample type: serum, plasma, tissue homogenates and other biological fluids
    Assay length: 3.5h
    Research Area: Cell proliferation
    Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to MTOR(Serine/threonine-protein kinase mTOR). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to MTOR(Serine/threonine-protein kinase mTOR). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain MTOR(Serine/threonine-protein kinase mTOR), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of MTOR(Serine/threonine-protein kinase mTOR) in the samples is then determined by comparing the OD of the samples to the standard curve.

    標準曲線

    Concentration (ng/mL) OD Corrected OD
    20.00 2.035 1.948
    10.00 1.628 1.541
    5.00 1.251 1.164
    2.50 0.892 0.805
    1.25 0.614 0.527
    0.63 0.335 0.248
    0.32 0.215 0.128
    0.00 0.087 0.000

    精密度

    Intra-assay Precision (Precision within an assay):CV%<8%

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

    Inter-assay Precision (Precision between assays):CV%<10%

    Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

    回收率

    Matrices listed below were spiked with certain level of recombinant MTOR and the recovery rates were calculated by comparing the measured value to the expected amount of MTOR in samples.
    Matrix Recovery range Average
    serum(n=5) 80-92% 86%
    EDTA plasma(n=5) 80-97% 88%
    Heparin plasma(n=5) 80-95% 87%

    線性

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MTOR and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
    Matrix 1:2 1:4 1:8 1:16
    serum(n=5) 89-103% 82-95% 86-99% 87-98%
    EDTA plasma(n=5) 79-92% 86-97% 88-95% 91-103%
    Heparin plasma(n=5) 87-98% 92-104% 82-96% 85-97%
    俄罗斯XXXXXBBBBB