俄罗斯XXXXXBBBBB


    EN

    產品中心

    牛胰高血糖素(GC)酶聯免疫吸附檢測試劑盒
    ELK9240
    規格: 價格:
    48 T ¥1680.00
    96 T ¥2400.00

    Overview

    Product name: Cattle GC(Glucagon) ELISA Kit
    Reactivity: Human
    Alternative Names: GCG; GLP1; GLP2; GRPP; Glicentin-Related Polypeptide; Glucagen; Oxyntomodulin; Incretin hormone
    Assay Type: Competitive Inhibition
    Sensitivity: 7.54 pg/mL
    Standard: 1500 pg/mL
    Range: 23.44-1500 pg/mL
    Sample type: serum, plasma and other biological fluids
    Assay length: 2h
    Research Area: Endocrinology;
    Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Glucagon(GC) protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Glucagon(GC). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Glucagon(GC) in the samples is then determined by comparing the OD of the samples to the standard curve.

    標準曲線

    Concentration (pg/mL) OD Corrected OD
    1500.00 0.199 0.000
    750.00 0.389 0.000
    375.00 0.577 0.000
    187.50 0.856 0.000
    93.75 1.135 0.000
    46.88 1.583 0.000
    23.44 1.755 0.000
    0.00 2.375 0.000

    精密度

    Intra-assay Precision (Precision within an assay):CV%<8%

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

    Inter-assay Precision (Precision between assays):CV%<10%

    Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

    回收率

    Matrices listed below were spiked with certain level of recombinant GC and the recovery rates were calculated by comparing the measured value to the expected amount of GC in samples.
    Matrix Recovery range Average
    serum(n=5) 80-95% 87%
    EDTA plasma(n=5) 83-95% 89%
    Heparin plasma(n=5) 92-107% 99%

    線性

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GC and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
    Matrix 1:2 1:4 1:8 1:16
    serum(n=5) 85-93% 82-90% 93-102% 93-106%
    EDTA plasma(n=5) 87-101% 91-104% 79-94% 87-96%
    Heparin plasma(n=5) 82-95% 89-102% 85-92% 96-104%