国产69精品久久久久久妇女迅雷

<thead id="t9djn"><var id="t9djn"><ruby id="t9djn"></ruby></var></thead>

    <thead id="t9djn"></thead>
    <big id="t9djn"><progress id="t9djn"><cite id="t9djn"></cite></progress></big>
      <thead id="t9djn"></thead>

      <big id="t9djn"><progress id="t9djn"><cite id="t9djn"></cite></progress></big>
      EN

      產品中心

      通用促卵泡素(FSH)酶聯免疫吸附檢測試劑盒
      ELK9279
      規格: 價格:
      48 T ¥1960.00
      96 T ¥2800.00

      Overview

      Product name: General FSH(Follicle Stimulating Hormone) ELISA Kit
      Reactivity: General
      Alternative Names: FSH-B; FSH-beta
      Assay Type: Competitive Inhibition
      Sensitivity: 0.67 mIU/mLmIU/mL
      Standard: 0.67 mIU/mL
      Range: 1.57-100mIU/mL
      Sample type: Serum, plasma and other biological fluids
      Assay length: 2h
      Research Area: Endocrinology;Reproductive science;Genetic science;Hormone metabolism;
      Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Follicle Stimulating Hormone(FSH) protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Follicle Stimulating Hormone(FSH). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Follicle Stimulating Hormone(FSH) in the samples is then determined by comparing the OD of the samples to the standard curve.

      標準曲線

      Concentration (mIU/mL) OD Corrected OD
      100.00 0.212 0.000
      50.00 0.357 0.000
      25.00 0.655 0.000
      12.50 0.895 0.000
      6.25 1.289 0.000
      3.13 1.537 0.000
      1.57 1.813 0.000
      0.00 2.101 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant FSH and the recovery rates were calculated by comparing the measured value to the expected amount of FSH in samples.
      Matrix Recovery range Average
      serum(n=5) 78-96% 87%
      EDTA plasma(n=5) 78-92% 85%
      Heparin plasma(n=5) 95-107% 101%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FSH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 81-92% 85-94% 87-105% 92-101%
      EDTA plasma(n=5) 79-90% 81-94% 93-107% 93-102%
      Heparin plasma(n=5) 95-103% 81-94% 93-107% 85-101%
      国产69精品久久久久久妇女迅雷